Vascular Response to Drug-Coated vs. Drug-Eluting Stents 1 and 12 Months After Implantation: The COLLABORATION Study
The COLLABORATION study showed that in patients with coronary artery disease, the polymer-free BioFreedom Biolimus A9 Coated Stent (PF-BCS) did not differ from the Xience Everolimus-Eluting Stent (DP-EES), which uses a durable polymer, in thrombus formation at 1 month and 12 months after implantation. Although there was no difference in thrombus formation at 1 and 12 months after implantation, the strut coverage and plaque stabilization at 12 months were better. Dr. Takayuki Ishihara of Kansai Rosai Hospital presented at the Hot-line Session of the 86th Annual Meeting of the Japanese Circulation Society.